All Titanium Series UPS units include an internal isolation transformer. This rugged design ensures consistent, reliable power quality to all instruments.

Category:

UPS Brochure UPS Drawing
Non-Matching Battery Cabinet Drawing
Maintenance Bypass Drawing
Maintenance Bypass w/ Kirk-Key Drawing
SNMP Manager Quick Guide
Modbus-manual-20200902
AS400+software1-quickguide-v4-20170330
Titanium Series UPS Internal Battery Cabinet Runtimes- Various Loads 

 

 

 

Features

    • Isolated Transformer:  All Titanium Series UPS units include an internal isolation transformer. This rugged design ensured low common mode noise and low normal mode noise.
    • In-rush Capabilities:  The Titanium Series UPS systems include a high in-rush capability. Supporting an overload for 150% will allow the user to properly size their UPS.
    • Customized Back Panels:  Back panels are customized per customer. Allows for specific designs to ensure all power requirements are supported.
    • External Maintenance Bypass Systems:  External Maintenance Bypass Systems are available in two types – isolated and non-isolated version. Consult factory for recommendations .

Specifications

 

MODEL TITANIUM SERIES UPS
5.2kVA (H) 6kVA (H) 8kVA (H) 10kVA (H)
Capacity 5.2kVA / 5.2kW 6kVA / 6kW 8kVA / 8kW 10kVA / 10kW
INPUT
Input Voltage (range) 208/220/230/240VAC / +28%/ -15% @ full load
Phase 1 Phase with neutral
Frequency Range 46Hz ~ 54Hz @ 50Hz System, 56Hz ~ 64Hz @ 60Hz System
Power Factor ≧ 0.99 at 100% Load
OUTPUT
Output Voltage 104/110/115/120/208/220/230/240
Phase 1 Phase with neutral
Frequency Sync Range 46Hz ~ 54Hz @ 50Hz System, 56Hz ~ 64Hz @ 60Hz System, (Batt Mode) +/- 0.1% Hz
Output THD ≦ 2% at 100% Linear Load / ≦ 4% at 100% Non-linear Load (PF≥0.8)
Voltage Regulation ± 1%
Overload – AC Mode 100%~110% for 1hr / 110-130% for 1min / >130%: 1sec
Overload – Battery Mode 100-110%: 30sec / 110-130%: 10sec / >130%: 1sec
Current Crest Ratio 3:1 Max
EFFICIENCY
AC Mode 90%
Battery Mode 88%
ECO Mode 97%
BATTERY
Battery Voltage 240, Nominal, 270 Float
Battery Backup Time 8min 7min 4min 2min
Recharge Time 7 hours at 90%
Quantity 20
Internal Batteries 20 x 9AH 20 x 9AH 20 x 9AH 20 x 9AH
PHYSICAL
Dimensions WxDxH 9.8″W x 28.2″D x 32.5″H
Weight (lbs) 266 266 301 301
ENVIRONMENT
Operating Temperature 0-40°C (the battery life will decrease when > 25°C)
Operating Humidity <95% non-condensing
Operating Altitude ft (m) 2,000ft
Heat Dissipation (BTU/Hr) 1970 2530 3372 4215
Acoustic Noise Level 55-60dB at 1 meter 60dB at 1 meter
COMMUNICATION
RS-232 or USB Supports Windows® 2000/2003/XP/Vista/2008/7/8/10, Linux, Unix, and MAC
MODBUS Card Power Management with MODBUS communication
Optional SNMP Power management from SNMP manager and web browser
AGENCY APPROVAL
Safety UL 1778 / IEC 62040-2:2018
Environmental FCC Part 15J, Class A